Flare ignition device in oilfield drilling is mainly used to burn the exhausted poisonous gas from poor boy degasser. Usually, the flare ignition device will be working together with the mud gas separator to light harmful gas.
Installation considerations of ignition device
1. In the transportation, and lifting process of the burner should avoid damaging the insulation of ignition wire.
2. We must select the open air to install the burner.
3. The pedestal of burner should be positive anchoring with foundation, when requested to use guy rope.
4. Flare ignition device should install the place with good environment to prevent electronic circuit is not affected by moisture pick-up.
5. Matched use with mud gas separator in drilling process.
6. Pay more attention on torch to prevent any break on ignition guideline insulation. When we install torch, please consider to choose safe place with lower fire possibility. The torch base must be stable with level pedestal and use rope to assist if necessary.
Ignition device maintenance measures
1. The instrument should works in the cool and dry place, don't shine for a long time and forbidden to insolate, rain.
2. If the remote control can't get the signal under normal circumstances, and the remote control ejector indicator is darken shows remote control battery is under voltage, need to change battery.
3. In order to ensure the accumulator can normally work when have no alternating current, when have current request use 220v alternating current.
4. The ignition needle need often be scrubbed, eliminated carbon deposition and sundries.